栋楼临水补充施工方案济南奥体D中国建筑一局(集团)有限公司目录一编制依据...................................................................................................................2二现场概况...................................................................................................................2三补充方案编制内容...................................................................................................2四施工组织.................................................................................................................7五临时用水管道安装工艺及冬季防护.......................................................................9六临水系统维护与管理...............................................................................................9七安全文明施工.........................................................................................................10八附图.........................................................................................................................111栋楼临水补充施工方案济南奥体D中国建筑一局(集团)有限公司一、编制依据(一)《工业金属管道工程施工及验收》(GB50235-97)(二)《济南市建设工程施工现场消防安全管理办法》(三)《建筑给排水及采暖工程施工质量验收规范》(GBJ50242-2002)(四)《建筑设计防火规范》(GB50016-2006)(五)《建设工程施工现场消防安全技术规范》(GB50720—2011)(六)施工现场平面布置图(七)《临水施工组织设计方案》二、现场概况现场主要用水设备、临建情况详见《临水施工组织设计方案》现场临水平面布置图。三、补充方案编制内容本方案为原临水设计施工方案的补充深化方案,涉及主楼临时消防(生产)管道材质选用、设备选型确定、设备运行工况、主体结构及粗、精装阶段临时给水管道布置、消火栓定位、维护及使用管理、泵房运行管理及增设楼内排水系统等内容。一)临时用水水源临时消防及生产用水(以下简称临水)由室外临时消防环线引入,引入干管为DN100焊接钢管,借用B1层正式工程P-2排水出户刚性防水套管,避免破坏结构,引入后楼内供
临水方案成稿 来自淘豆网www.taodocs.com转载请标明出处.